LT Power Cables

SiHF-GLS

thumbnail

Application

These are silicone multicore cables with galvanized steel braiding for robust application.

These cables are used in the areas having large band of extreme temperatures and can be used in the areas with increased mechanical stress.

They are especially used in steel production industries, cement industries, glass industries, aviation industries, ship buildings, etc.

Standard

Adapted to DIN VDE 0250 part 1 and part 816.

Technical Data

Voltage Rating : UO / U - 300 / 500V

Test Voltage : 2000V

Temperature Range : -50°C to +180°C (up to + 220°C for short time)

Temperature Limit at the Conductor : In operation +180°C

Insulation Resistance : Min. 200 MΩ x km

Minimum Bending Radius : Flexing 20 x cable ø. Fixed installation 4 x cable ø

Cable Construction

Tinned copper conductor to Cl. 5, EN 60228.

Silicone core insulation.

Core identification to DIN VDE 0293 - 308 colour coded or black cores with continuous white numbers.

For 2 - cores brown, blue.

For 3 - cores and above cable provided without protective conductor.

For 6 - cores and above all black cores with number coding.

Cores stranded in layers with optimal lay - length.

Outer jacket of Silicone.

Jacket colour - red brown.

Glass fibre tape over the jacket.

Galvanised steel wire outer braiding.

Properties

Galvanised steel braid over the sheath protects against the external mechanical damages.íhe cable has better durability in harsh environments and applications compared to the conventional silicone cables.

Advantages : Hardly changes of dielectric strength and the insulation resistance also at high temperatures, high ignition or flash point, in case of fire, forms an insulating layer of SiO2.

In case of fire, it forms an insulating layer of SiO2

Resistant to : High molecular oils, fats from vegetables and animals, alcohols, plasticisers and clopenes, diluted acids, dyes and salt dissolution, oxidation substances, tropical influences and weather, lake water, oxygen and UV.

Halogen - Free : According to IEC 60754 - 2.

Behavior in Fire : Flame propagation test according to EN 60332 - 1 - 2.

Cable Design Parameters

Part Number Nominal Cross Sectional Area (Sq. mm) Approx. Cable Diameter (mm) Approx. Copper Weight (kg/km) Approx. Cable Weight (kg/km)
80400201075  2 x 0.75 7.6 13 94
80400311075  3 x 0.75 8 19.6 102
80400411075  4 x 0.75 8.6 26.1 121
80400511075  5 x 0.75 9.3 32.6 134
80400711075  7 x 0.75 10.3 45.6 159
80400200001  2 x 1 7.8 17.4 103
80400310001  3 x 1 8.2 26.1 112
80400410001  4 x 1 8.9 34.8 131
80400510001  5 x 1 9.6 43.5 148
80400710001  7 x 1 10.6 60.8 180
80400201105  2 x 1.5 8.7 25.5 124
80400311105  3 x 1.5 9.2 38.2 142
80400411105  4 x 1.5 9.9 50.9 162
80400511105  5 x 1.5 10.7 63.7 189
80400711105  7 x 1.5 11.9 89.1 229
80401211105  12 x 1.5 15.3 152.8 355
80400201205  2 x 2.5 10 42.4 167
80400311205  3 x 2.5 10.6 63.7 191
80400411205  4 x 2.5 11.5 84.9 224
80400511205  5 x 2.5 12.5 106.1 260
80400711205  7 x 2.5 13.9 148.5 321
80400200004  2 x 4 11.8 67.5 234
80400300004  3 x 4 12.5 101.2 269
80400400004  4 x 4 14 135 329
80400500004  5 x 4 15.1 168.7 385
80400200006  2 x 6 14.2 101.2 324
80400300006  3 x 6 15 151.8 376