PVC BATTERY CABLE
Standard
Adapted to BS 6862
Temperature Range (3000 Hrs)
-40°C to + 90°C
Cable Construction
Bare copper strands as per EN 60228, class 6
Packing
Available in wooden drums.
Conductor Bunch Variants
Normal flex and Super flex
Special Elastomeric Insulation
Thermoplastic Elastomer Vulcanizate
Special Properties
Acid Resistance Test: In sulphuric acid of specific gravity 1.28 at a temperature of 160°C to 210°C and check the cable after 60 hrs.
No effect on insulation. Insulation free from deformation and shrinkage
Chemical Resistance: Resistant to ozone, acids, solvents, detergents, vaseline and oils.
Cable Design Parameters
Super Flex
Nominal
Cross-Section (mm²)
|
No. of Strands
|
Max. Strand Diameter (mm)
|
Outer Diameter (mm)
|
Max. DC Conductor Resistance at 20oC (Ω/km)
|
25
|
784
|
0.20
|
11.1
|
0.78
|
35
|
1176
|
0.20
|
12.8
|
0.554
|
50
|
1568
|
0.20
|
14.0
|
0.386
|
70
|
2205
|
0.20
|
16.0
|
0.272
|
95
|
2989
|
0.20
|
18.0
|
0.206
|
Nominal
Cross-Section (mm²)
|
No. of Strands
|
Max. Strand Diameter (mm)
|
Outer Diameter (max.) (mm)
|
Max. DC Conductor Resistance at 20oC (Ω/km)
|
25
|
816
|
0.20
|
11.1
|
0.78
|
35
|
1144
|
0.20
|
12.8
|
0.554
|
50
|
1662
|
0.20
|
14.0
|
0.386
|
70
|
2346
|
0.20
|
16.0
|
0.272
|
95
|
3050
|
0.20
|
18.0
|
0.206
|
|
|
|
|
|