FLYW
Application
These are auto cables ideal for use in automotives with hot pressure resistance
Standard
In accordance to ISO 6722-1
Temperature Range (3000 Hrs)
-40°C to +125°C
Cable Construction
Soft annealed electrolytic copper Cu-ETP1 according to DIN EN 13602, bare conductor construction according to ISO 6722-1 Soft PVC insulation with properties according to ISO 6722-1, Class C
Packing
Available in 100 mtrs. Longer length available in spools or wooden drums.
Special Properties
Hot pressure resistance test at 120°C. Suitable for applications inside the engine compartment.
Nom.
Cross-Section (mm²)
|
No. of Strands
|
Max. Strand Diameter (mm)
|
Max. Conductor Diameter (mm)
|
Max. DC Conductor Resistance at 20oC (Ω/km)
|
Nominal Insulation Thickness (mm)
|
Overall Diameter (mm)
|
Approx. Weight (Kg/Km)
|
Max.
|
Tolerance
|
0.5
|
16
|
0.21
|
1.0
|
37.1
|
0.6
|
|
8.0
|
2.3
|
-0.3
|
0.75
|
24
|
0.21
|
1.2
|
24.7
|
0.6
|
2.5
|
-0.3
|
11.0
|
1
|
32
|
0.21
|
1.35
|
18.5
|
0.6
|
2.7
|
-0.3
|
14.0
|
1.25*
|
16
|
0.33
|
1.7
|
14.9
|
0.6
|
2.95
|
-0.55
|
14.0
|
1.5
|
30
|
0.26
|
1.7
|
12.7
|
0.6
|
3.0
|
-0.3
|
19.0
|
2
|
28
|
0.31
|
2.0
|
9.42
|
0.6
|
3.3
|
-0.3
|
25.0
|
2.5
|
50
|
0.26
|
2.2
|
7.6
|
0.7
|
3.6
|
-0.3
|
31.0
|
3
|
60
|
0.26
|
2.4
|
6.0
|
0.7
|
4.1
|
-0.3
|
37.0
|
4
|
56
|
0.31
|
2.75
|
4.71
|
0.8
|
4.4
|
-0.4
|
47.0
|
5
|
65
|
0.33
|
3.1
|
3.94
|
0.8
|
4.9
|
-0.4
|
58.0
|
6
|
84
|
0.31
|
3.3
|
3.14
|
0.8
|
5.0
|
-0.4
|
68.0
|
8*
|
50
|
0.46
|
4.3
|
2.38
|
0.8
|
5.9
|
-0.9
|
88.0
|
10
|
80
|
0.41
|
4.5
|
1.82
|
1.0
|
6.5
|
-0.5
|
111.0
|
12**
|
96
|
0.41
|
5.4
|
1.52
|
1.0
|
7.4
|
-0.8
|
142.0
|
16
|
126
|
0.41
|
6.3
|
1.16
|
1.0
|
8.3
|
-0.6
|
179.0
|
20**
|
152
|
0.41
|
6.9
|
0.955
|
1.1
|
9.1
|
-1.0
|
218.0
|
25
|
196
|
0.41
|
7.8
|
0.743
|
1.3
|
10.4
|
-1.0
|
278.0
|