LT Power Cables

FLR13Y

thumbnail

Application

These are TPE-E insulated low tension automotive cables used in motor vehicles for lightings, signals and instrument panel circuits operating across wide range of extreme temperature.

Standard

In accordance to ISO 6722-1 class D

Temperature Range (3000 Hrs)

-40°C to +150°C

Cable Construction

Soft annealed electrolytic copper Cu-ETP1 according to DIN EN 13602 ,bare conductor construction acc. To ISO 6722-1 Tinned copper available on request. TPE-E (Thermoplastic Elastomer)

Packing

Packing available in 100 mtrs. Longer length available in spools.

Cable Design Parameters

Nom. Cross- Section (mm²)

No. of Strands

Max. Strand Diameter (mm)

Max. Conductor Diameter (mm)

Max. DC Conductor Resistance at 20oC (Ω/km)

Min. Insulation Thickness (mm)

Overall Diameter

Min.

Max.

FLR13Y - TYPE A

0.22

7

0.21

0.7

84.8

0.20

1.1

1.2

0.35

7

0.26

0.8

54.4

0.20

1.2

1.3

0.5

19

0.19

1.0

37.5

0.22

1.4

1.6

0.75

19

0.23

1.2

24.7

0.24

1.7

1.9

1

19

0.26

1.35

18.5

0.24

1.9

2.1

1.5

19

0.32

1.7

12.7

0.24

2.2

2.4

2

19

0.37

2.0

9.42

0.28

2.5

2.8

2.5

19

0.41

2.2

7.6

0.28

2.7

3.0

FLR13Y - TYPE B

0.35

12

0.21

0.9

54.4

0.20

1.2

1.4

0.5

16

0.21

1.0

37.5

0.22

1.4

1.6

0.75

24

0.21

1.2

24.7

0.24

1.7

1.9

1

32

0.21

1.35

18.5

0.24

1.9

2.1

1.5

30

0.26

1.7

12.7

0.24

2.2

2.4

2

30

0.31

2.0

9.42

0.28

2.5

2.8

2.5

50

0.26

2.2

7.60

0.28

3.7

3.0

4

56

0.31

2.75

4.71

0.32

3.4

3.7

6

84

0.31

3.3

3.14

0.32

4.0

4.3