WELDEX-IS 9857
Application
For use between welding generators and hand electrodes and the workpiece .
For use in automobile industries, ship building, in transport and conveyor system, tool making machinery, welding robots, etc.
Standard
Standard
Adapted to IS:9857, IS:6380, IS:8130.
Technical Data
Voltage Rating : 450V a. c. rms.
Test Voltage : 1000V
Temperature Range : -20°C to +60°C
Minimum Bending Radius : 5 x cable diameter
Cable Construction
Super fine strands of annealed bare copper according to IS:8130, Cl. 6. Elastomeric insulation type SE-1 conforming to the requirements of IS:6380.
Properties
The heavy duty welding cable is resistant to flame, oil, abrasions, tar and grease. Suitable for use in open air, in dry as well as damp interiors.
The high degree of flexibility does not form knots on the cable which could lead to internal break of conductors.
Part Number | Nominal Cross-Sectional Area (Sq. mm) | Max. Strand Diameter (mm) | Max. DC Conductor Resistance (Ω/km) | Nominal Insulation Thickness (mm) | Nominal Cable Diameter (mm) |
120500100016 |
16 |
0.21 |
1.21 |
2.0 |
9.2 |
120500100025 |
25 |
0.21 |
0.78 |
2.0 |
10.5 |
120500100035 |
35 |
0.21 |
0.554 |
2.0 |
11.5 |
120500100050 |
50 |
0.31 |
0.386 |
2.2 |
13.5 |
120500100070 |
70 |
0.31 |
0.272 |
2.4 |
15.5 |
120500100095 |
95 |
0.31 |
0.206 |
2.6 |
17.7 |
Current Rating of General Service Normal Duty Elastomeric Compound Covered Cable with Copper Conductor
Part Number | Nominal Cross Sectional Area of Conductor (Sq. mm) | Current Rating at a Maximum Duty Cycle of |
100% A | 85% A | 60% A | 30% A | 20% A |
120500100016 |
16 |
94 |
102 |
121 |
172 |
210 |
120500100025 |
25 |
125 |
136 |
161 |
228 |
279 |
120500100035 |
35 |
156 |
169 |
201 |
285 |
349 |
120500100050 |
50 |
197 |
214 |
254 |
360 |
440 |
120500100070 |
70 |
248 |
269 |
320 |
453 |
555 |
120500100095 |
95 |
299 |
342 |
386 |
546 |
669 |
Note :
Ambient air temperature = 30°C. Maximum conductor temperature = 60°C