Technical Data

Nominal Voltage : 300V

Test Voltage : 2000V

Test Voltage (Spark Test)

AWG 26 - 20 : 4kV, AWG 10 -18: 5kV

Temperature Range : Flexible -5°C to + 105°C. Fixed installation -20°C to + 105°C CSA - AWM I A/B

Temperature at Conductor : Max. UL and CSA : +105°C

Bending Radius : Flexing 10 x cable ø. Fixed installation 5 x cable ø

Cable Construction

Annealed plain or tinned stranded copper conductor.

PVC - core insulation according to UL - Standard 1581, Class 43 Tab. 50.182, heat and damp resistant.

Properties

Conditionally resistant to oils, solvents, acids and dyes.

PVC self - extinguishing and flame retardant, test method to UL VW-1 and CSA FT 1 / FT 2

Cable Design Parameters

Kindly complete the part numbers for these cables by adding the suffix (in place of ‘xx’) for the insulation colour required: 01 – green, 02 – black, 03 – red, 04 – blue, 05 – yellow, 06 – green/yellow, 07 – white, 08 -Violet, 09 – brown, 10 – orange, 11 – pink, 12 – grey, 13 – light blue.

Part Number AWG No. No. of Cores & Nominal Cross Sectional Area (Sq. mm) Approx. Cable Diameter (mm) Approx. Copper Weight (kg/km) Approx Cable Weight (kg/km)
06040101xx30 26 1 x 0.14 1.3 1.4 3.0
06040102xx30 24 1 x 0.21 1.5 2.1 4.3
06040103xx30 22 1 x 0.33 1.6 3.5 5.8
06040104xx30 20 1 x 0.52 1.8 5.2 8.0
06040105xx30 18 1 x 0.82 2.1 8.3 12
06040106xx30 16 1 x 1.32 2.5 13.5 18.4
06040107xx30 14 1 x 2.08 3.0 20.4 27.3
06040108xx30 12 1 x 3.31 3.5 32.5 41.3
06040109xx30 10 1 x 5.26 4.1 51.7 62.8