LT Power Cables

FLRYW

thumbnail

Application

These are thin wall auto cables with hot pressure resistant properties

Standard

In accordance to ISO 6722-1

Temperature Range (3000 Hrs)

-40°C to +125°C

Cable Construction

Soft annealed electrolytic copper Cu-ETP1 according to DIN EN 13602, bare or tinned construction acc. to ISO 6722-1 Special PVC insulation with properties according to ISO 6722-1, Class C

Packing

Available in 100 mtrs. Longer length available in spools or wooden drums.

Cable Design Parameters

Nom. Cross- Section (mm²)

No. of Strands

Max. Strand Diameter (mm)

Max. Conductor Diameter (mm)

Max. DC Conductor Resistance at 20oC (Ω/km) (Bare/Tinned)

Min. Insulation Thickness (mm)

Overall Diameter

Approx. Weight (Kg/Km)

Max.

Tolerance

FLRYW - TYPE A

0.35

7

0.26

0.8

54.4

55.5

0.20

1.3

-0.1

5.0

0.5

19

0.19

1.0

37.5

38.2

0.22

1.6

-0.2

7.0

0.75

19

0.23

1.2

24.7

25.4

0.24

1.9

-0.2

9.0

1.0

19

0.26

1.35

18.5

19.1

0.24

2.1

-0.2

11.0

1.25

19

0.30

1.5

14.9

15.9

0.24

2.3

-0.2

12.0

1.5

19

0.32

1.7

12.7

13.0

0.24

2.4

-0.2

16.0

2.0

19

0.37

2.0

9.42

9.69

0.28

2.8

-0.3

22.0

FLRYW - TYPE B

0.35

12

0.21

0.9

54.4

55.5

0.20

1.4

-0.2

5.0

0.5

16

0.21

1.0

37.5

38.2

0.22

1.6

-0.2

7.0

0.75

24

0.21

1.2

24.7

25.4

0.24

1.9

-0.2

9.0

1.0

32

0.21

1.35

18.5

19.1

0.24

2.1

-0.2

11.0

1.25*

16

0.33

1.5

14.9

15.9

0.24

2.3

-0.2

12.0

1.5

30

0.26

1.7

12.7

13.0

0.24

2.4

-0.2

16.0