LT Power Cables

RATNAFLEX FLEXIBLE

thumbnail

Application

Cable designed for internal wiring in switch control, relay and instrumentation panels of power switchgear and for purposes such as stationary, static appliances, internal connectors in rectifier equipment, motor starters and controllers.

PVC 70°C cables suitable for general wiring in control cabinets, panels and power switchgear.

FR PVC 70°C cables suitable for ambient wiring in control cabinets, panels and power switchgear for enhanced safety. HR PVC 85°C cables suitable for higher ambient wiring in control cabinets, panels and power switchgear.

HR FR PVC 85°C cables suitable for higher ambient wiring in control cabinets, panels and power switchgear and enhanced safety.

FR-LSH PVC 70°C cables are suitable for wiring in public places like schools, hospitals, theatres, etc. These are also suitable for fire prone areas in industries and commercial infrastructure.

LS0H 70°C cables, suitable for critical and dense wiring for utmost safety of public like schools, hospitals, theatres, etc. These are also suitable for fire prone areas.

Technical Data

Approvals : IS 694 marked, FIA / TAC

Conductor : Electrolytic grade annealed copper

Voltage : Up to and including 1100V

Packing : Standard packing of 100 mtr. in coil. Longer length available on request

Variants Available

Product Type Size Range Specifications
RR KABEL 0.5 & 0.75 Sq. mm IS 694, IS 8130 Class 5, IS 5831 Type D
RATNAFLEX 1 to 4 IS 694, IS 8130 Class 5, IS 5831 Type D
RR KABEL FR 0.5 to 300 Sq. mm IS 694, IS 8130 Class 5, IS 5831 Type D (FR)
RR KABEL FR-LSH 0.5 to 150 Sq. mm IS 694, IS 8130 Class 5, IS 5831 Type D (FR-LSH)
RR KABEL HR 0.5 & 0.75 Sq. mm, 6 to 16 Sq. mm IS 694, IS 8130 Class 5, IS 5831 Type C (HR)
RATNAFLEX HR 1 to 4 & 25 to 300 Sq. mm IS 694, IS 8130 Class 5, IS 5831 Type C (HR)
RR KABEL HR FR 0.5 to 300 Sq. mm IS 694, IS 8130 Class 5, IS 5831 Type C (HR FR)
RR KABEL LS0H* 0.5 to 240 Sq. mm EN 60228 class 5, Type LS0H TI-7 BS EN 50363-7


Cable Design Parameters

Kindly complete the part numbers for these cables by adding the suffix (in place of 'xx') for the colour required: 01 - green, 02 - black, 03 - red, 04 - blue, 05 - yellow, 06 - green/yellow, 07 - white, 08 - violet, 09 - brown, 10 - orange, 11 - pink, 12 - grey.

By adding the suffix (in place of 'y') for the insulation material required: 1 – PVC 70°C, 2 - PVC FR 70°C, 3 - PVC HR 85°C, 4 - PVC HR 85°C +FR, 5 - PVC FR-LSH 70°C, 7 - LS0H 70°C.

Part Number Nominal Cross Sectional Area (Sq. mm) No of Strands/Max. Strand Diameter (mm) Nominal Insulation Thickness (mm) Maximum Diameter Over Insulation (mm)
02010101xxy0 0.5 16/0.2 0.6 2.6
02010102xxy0 0.75 24/0.2 0.6 2.8
02010103xxy0 1 32/0.2 0.6 3.0
02010104xxy0 1.5 30/0.25 0.6 3.4
02010105xxy0 2.5 50/0.25 0.7 4.1
02010106xxy0 4 56/0.3 0.8 4.8
02010107xxy0 6 84/0.3 0.8 5.3
02010108xxy0 10 140/0.3 1.0 7.0
02010109xxy0 16 126/0.4 1.0 8.1
02010110xxy0 25 196/0.4 1.2 10.2
02010111xxy0 35 276/0.4 1.2 11.7
02010112xxy0 50 396/0.4 1.4 13.9
02010113xxy0 70 360/0.5 1.4 16.0
02010114xxy0 95 480/0.5 1.6 18.2
02010115xxy0 120 608/0.5 1.6 20.2
02010116xxy0 150 750/0.5 1.8 22.5
02010117xxy0 185 931/0.5 2.0 24.9
02010118xxy0 240 1200/0.5 2.2 28.4
02010119xxy0 300 1500/0.5 2.4 31.0