LT Power Cables

FLRY n x (TWISTED CABLES)

thumbnail

Application

These are unsheathed twisted wires used in automobiles

Standard

In accordance to ISO 6722-1

Temperature Range (3000 Hrs)

-40°C to +105°C

Cable Construction

Soft annealed electrolytic copper Cu-ETP1 according to DIN EN 13602, bare or tinned copper construction acc. to ISO 6722-1 PVC with properties according to according to ISO 6722-1, Class B

Special Properties

Higher heat resistance. Tinned copper conductor. Other lay lengths available on request.

Packing

Available in 100 mtrs. Longer length available in spools or wooden drums.

Cable Design Parameters

No. of Cores x Nom. Cross- Section (mm²)

No. of Strands

Max. Strand Diameter (mm)

Max. Conductor Diameter (mm)

Max. DC Conductor Resistance at 20oC (Ω/km)

Min. Insulation Thickness (mm)

Core Diameter (Max.) (mm)

Lay Length

(Nom.) (mm)

Outer Diameter (Max.)(mm)

Approx. Weight (Kg/Km)

2x0.35

7

0.26

0.8

52.0

0.20

1.3

16

2.6

9.0

2x0.35

7

0.26

0.8

52.0

0.20

1.3

20

2.6

9.0

2x0.35

7

0.26

0.8

52.0

0.20

1.3

30

2.6

9.0

2x0.5

19

0.19

1.0

37.1

0.22

1.6

15

3.2

13.0

2x0.5

19

0.19

1.0

37.1

0.22

1.6

30

3.2

13.0

2x0.5

16

0.21

1.0

37.1

0.22

1.6

20

3.2

13.0

2x0.5

16

0.21

1.0

37.1

0.22

1.6

30

3.2

13.0

3x0.5

19

0.19

1.0

37.1

0.22

1.6

30

3.5

20.0

3x0.5

16

0.21

1.0

37.1

0.22

1.6

40

3.5

20.0

2x0.75

24

0.23

1.2

24.7

0.24

1.9

30

3.8

18.0

2x0.75

19

0.21

1.2

24.7

0.24

1.9

30

3.8

18.0

3x0.75

19

0.23

1.2

24.7

0.24

1.9

30

4.1

27.0

2x1

19

0.26

1.35

18.5

0.24

2.1

30

4.2

22.0

2x1

32

0.21

1.35

18.5

0.24

2.1

30

4.2

22.0

3x1

32

0.21

1.35

18.5

0.24

2.1

25

4.5

33.0

4x1

19

0.26

1.35

18.5

0.24

2.1

30

5.1

44.0

2x1.5

19

0.32

1.7

12.7

0.24

2.4

30

4.8

32.0

2x2.5

50

0.26

2.2

7.8

0.28

3.0

30

6.0

52.0

5x2.5

50

0.26

2.2

7.8

0.28

3.0

50

8.1

130.0

6x2.5

50

0.26

2.2

7.8

0.28

3.0

55

9.0

156.0