LT Power Cables

FL11Y

thumbnail

Application

These are automotive cables for starting and charging application in motorcycles and other motor vehicles. The cable design makes it suitable for harsh environment and robust applications.

Standard

In accordance to ISO 6722-1

Temperature Range (3000 Hrs)

-40°C to +110°C

Cable Construction

Soft annealed electrolytic copper Cu-ETP1 according to DIN EN 13602, bare construction acc. To ISO 6722-1 TPE-U (Thermoplastic polyurathane elastomer) according to ISO 6722-1, Class B

Packing

Available in 100 mtrs. Longer length available in spools or wooden drums.

Cable Design Parameters

Nom. Cross- Section (mm²)

No. of Strands

Max. Strand Diameter (mm)

Max. Conductor Diameter (mm)

Max. DC Conductor Resistance at 20oC (Ω/km)

Nominal Insulation Thickness (mm)

Overall Diameter

Approx. Weight (Kg/Km)

Max.

Tolerance

6

84

0.31

3.3

3.14

0.80

5.0

-0.4

66.0

10

80

0.41

4.5

1.82

1.00

6.5

-0.5

109.0

16

126

0.41

6.3

1.16

1.00

8.3

-0.6

176.0

25

196

0.41

7.8

0.743

1.30

10.4

-0.7

273.0

35

276

0.41

9.0

0.527

1.30

11.6

-0.6

355.0

50

396

0.41

10.5

0.368

1.50

13.5

-2.0

511.0

70

360

0.51

12.5

0.259

1.50

15.5

-2.0

705.0

95

475

0.51

14.8

0.196

1.60

18.0

-2.0

905.0

120

608

0.51

16.5

0.153

1.60

19.7

-2.0

1170.0