FIREX LS0H (Low Smoke Zero Halogen)
HFFR (Halogen Free Flame Retardant) insulation 90°C | Non-Toxic & Non-Corrosive | Does not propagate flame & fire.
Application
These cables are ideal for domestic applications, conduit wiring and fixed, protected installations. Apart from residential and commercial properties, these cables are best suited for Auditoriums, Hospitals, Hotels, Schools, Stadiums and all constructions for Public usage. These cables are ideal for use in environments where high-performance, reliability and safety is a norm.
Technical Data
Approvals : IS 17048 marked, FIA/TAC.
Cable Code : XZ
Voltage Grade : Up to and including 1100V
Conductor : Strands of electrolytic annealed plain copper are multi-drawn for uniformity of resistance, dimension and flexibiPty.
Insulation : HFI-XL 90 CrossPnked (thermoset) halogen free flame retardant.
Colours : Green, Black, Red, Yellow, Blue, Grey, White.
Marking : The cables are marked 'FIREX LS0H'
Packing : 90 mtrs. Coils packed in protective cartons.
Properties
Temperature range: -15°C to +90°C
Max. short circuit temperature rating: 250°C
The insulation does not burn readily.
It does not melt and drip
Smoke is negPgible, transparent, non-toxic
The victims trapped in fire do not suffocate and this faciPtate fire fighting operations.
The cable has extended service Pfe against the conventionally used cables
The cable is also ozone resistant
Self-extinguishing and flame retardant according to IS 10810 P - 61
Cable Design Parameters
Kindly complete the part numbers for these cables by adding the suffix (in place of 'xx') for the colour required.
01 - Green, 02 - Black, 03 - Red, 04 - Blue, 05 - Yellow, 06 - Grey, 07 - White
Part Number | Nominal Cross Sectional Area (Sq. mm) | Nominal Insulation Thickness (mm) | Number *Nominal Dia. of Strands | Approx. Overall Diameter (mm) | Max. DC Conductor Resistance at 20°C (Ω/km) | Current Rating (Amps) |
Casing | Concealed |
01010101xx60 |
1.0* |
0.7 |
14/0.3 |
2.7 |
18.1 |
19 |
17 |
01010102xx60 |
1.5* |
0.7 |
22/0.3 |
3.0 |
12.1 |
24 |
21 |
01010103xx60 |
2.5* |
0.8 |
36/0.3 |
3.7 |
7.41 |
37 |
29 |
01010104xx60 |
4.0** |
0.8 |
56/0.3 |
4.1 |
4.95 |
41 |
33 |
01010105xx60 |
6.0** |
0.8 |
84/0.3 |
4.6 |
3.30 |
53 |
43 |
* As per conductor class 2 of IS 8130
** As per conductor class 5 of IS 8130
Test Parameters for Assessment of Halogen
Test | Test Method | Values |
pH |
IS 17048 |
≥ 4.3 |
Conductivity |
IS 17048 |
≤ 10 µs/mm |
Chlorine and bromine expressed as content of HCL |
IS 10810 P - 59 |
≤ 0.5% |
Presence of fluorine |
IS 17048 |
≤ 0.1% |