LT Power Cables

SERVO FD 85810

thumbnail

Application

For use in power chains or moving machine parts. Suitable for use in measuring, control and regulating circuits. Power circuits for electrical equiment used in automation engineering assembly lines, production lines and in all kinds of machines and plant engineering.

Standard

Requirement adapted to DIN VDE 0245, 0281

Technical Data

Nominal Voltage : UO / U 300 / 500V

Temperature Range : Flexing -5°C to +70°C. Fixed installation -30°C to +70°C

Minimum Bending Radius : Flexing 7.5 x cable ø. Fixed installation 4 x cable ø

Test Voltage : 4000V

Insulation Resistance : Min. 20 GΩ x cm

Cable Construction

Bare copper, fine wire conductors according to EN 60228 Cl. 6,

Core insulation of special PVC TI2 EN 50363-3.

Black core with continuous white numbering according to DINVDE 0293.

Green-yellow earth core in the outer layer (3 cores and above).

Non-woven wrapping.

Outer sheath of special PVC, TM2 to DIN/BS EN 50363-4.1.

Colour grey (RAL 7001).

Properties

PVC self-extinguishing and flame retardant according to EN 60332-1-2.

This cable is also available with UV resistance property as SERVO FD

85810 UV Kindly add 'UV' after the part no. for UV resistant cable.

UV resistant to ASTM G 154.

Cable Design Parameters

Part Number No. of Cores & Nominal Cross Sectional Area (Sq. mm) Approx. Cable Diameter (mm) Approx. Copper Weight (kg/km) Approx. Cable Weight (kg/km)
041200201050 2 x 0.5 5.3 8.7 39
041200311050 3G 0.5 5.7 13.0 48
041200411050 4G 0.5 6.3 17.4 60
041200511050 5G 0.5 6.8 21.7 71
041200711050 7G 0.5 8.0 30.4 99
041201211050 12G 0.5 9.5 52.1 147
041201811050 18G 0.5 11.4 78.1 214
041202511050 25G 0.5 13.7 108.5 306

Part Number No. of Cores & Nominal Cross Sectional Area (Sq. mm) Approx. Cable Diameter (mm) Approx. Copper Weight (kg/km) Approx. Cable Weight (kg/km)
041203011050 30G 0.5 14.3 130.2 344
041203411050 34G 0.5 15.6 147.5 403
041205011050 50G 0.5 18.5 216.9 574
041200201075 2 x 0.75 5.7 13.0 48
041200311075 3G 0.75 6.2 19.5 60
041200411075 4G 0.75 6.8 26.0 75
041200511075 5G 0.75 7.4 32.5 90
041200711075 7G 0.75 8.9 45.6 129
041201211075 12G 0.75 10.6 78.1 194
041201611075 16G 0.75 12.0 104.1 253
041201811075 18G 0.75 12.7 117.2 283
041202511075 25G 0.75 15.2 162.7 402
041200200001 2 x 1 6.1 17.4 57
041200310001 3G 1 6.6 26.0 72
041200410001 4G 1 7.3 34.7 90
041200510001 5G 1 8.0 43.4 110
041200710001 7G 1 9.6 60.7 157
041201210001 12G 1 11.4 104.1 237
041201410001 14G 1 12.3 121.5 276
041201610001 16G 1 13.0 138.8 311
041201810001 18G 1 13.9 156.2 353
041202510001 25G 1 16.4 216.9 491
041202610001 26G 1 16.4 225.6 498
041203410001 34G 1 18.9 295.1 658
041204110001 41G 1 20.6 355.8 786
041205010001 50G 1 22.3 433.9 936
041206510001 65G 1 25.4 564.1 1215
041200201105 2 x 1.5 6.8 26.0 75
041200311105 3G 1.5 7.4 39.1 96
041200411105 4G 1.5 8.1 52.1 119
041200511105 5G 1.5 9.1 65.1 150
041200711105 7G 1.5 9.9 91.1 189
041201211105 12G 1.5 12.9 156.2 322
041201811105 18G 1.5 15.0 234.3 456
041202511105 25G 1.5 17.6 325.4 630
041202611105 26G 1.5 17.8 338.4 649

Part Number No. of Cores & Nominal Cross Sectional Area (Sq.mm) Approx. Cable Diameter (mm) Approx. Copper Weight (kg/km) Approx. Cable Weight (kg/km)
041203411105 34G 1.5 20.2 442.6 841
041204111105 41G 1.5 22.0 533.7 1006
041204211105 42G 1.5 22.0 546.7 1017
041205011105 50G 1.5 24.0 650.8 1210
041200311205 3G 2.5 9.0 65.1 148
041200411205 4G 2.5 10.0 86.8 188
041200511205 5G 2.5 11.2 108.5 235
041200711205 7G 2.5 12.5 151.9 307
041201211205 12G 2.5 16.0 260.3 513
041201411205 14G 2.5 17.2 303.7 595
041200310004 3G 4 10.6 104.1 217
041200410004 4G 4 11.7 138.8 274
041200510004 5G 4 13.1 173.6 343
041200410006 4G 6 13.9 208.6 398
041200510006 5G 6 15.5 260.8 496
041200410010 4G 10 17.6 358.5 658
041200510010 5G 10 19.6 448.2 819
041200410016 4G 16 21.0 565.0 983
041200510016 5G 16 23.6 706.2 1236

Note : * G = With green / yellow earth core , X = Without green / yellow earth core