RATNACOM
Application
Recommended for switchboard and telephone wiring in residentials and commercial infrastructure, for transmission of analog and digital.
signals, wiring in faxes, modems, alarm enunciators, data recording/acquisition systems and various communication devices.
Technical Data
Specifications : ITD-S/WS 113C
Conductor : The central conductor is made of solid electrolytic grade of copper.
Insulation : Premium quality grade polyethylene used on a special extruder. This offers for low attenuation.
Twisted Pairs : The cores are carefully twisted with optimal lays and bunched together to deliver minimised cross talk.
Jacket : Specially formulated flame retardant (FR) PVC.
Marking : The cables are marked 'RATNACOM FR’
Packing : Available in 90 mtr. length in polybag. Higher lengths available on special request.
Part Numbers | Size (mm) | No. of Pairs | Approx. Overall Diameter (mm) |
010600221040 |
0.4 |
2 |
3.9 |
010600321040 |
0.4 |
3 |
4.3 |
010600421040 |
0.4 |
4 |
4.7 |
010600521040 |
0.4 |
5 |
5.2 |
010601021040 |
0.4 |
10 |
6.5 |
010602021040 |
0.4 |
20 |
9.2 |
010600221050 |
0.5 |
2 |
4.2 |
010600321050 |
0.5 |
3 |
4.7 |
010600421050 |
0.5 |
4 |
5.1 |
010600521050 |
0.5 |
5 |
5.7 |
010601021050 |
0.5 |
10 |
7.0 |
010602021050 |
0.5 |
20 |
10.0 |
Electrical Parameters
Electrical Parameters | Size |
0.5 mm | 0.4 mm |
DC conductor resistance |
92.20 Ω/Km at 20°C max. |
143.0 Ω/Km at 20°C max. |
Mutual capacitance |
50 nF/km max. |
Insulation resistance in air |
10000 M-Ω/Km |
Capacitance unbalance – pair to pair |
250 pF/100m max. |
Capacitance unbalance – pair to ground |
330 pF/100m max. |
Resistance unbalance |
5% max. |