\ Param Enterprises : Authorized Distributor of Industrial and Electrical components
LT Power Cables

RATNACOM

thumbnail

Application

Recommended for switchboard and telephone wiring in residentials and commercial infrastructure, for transmission of analog and digital.

signals, wiring in faxes, modems, alarm enunciators, data recording/acquisition systems and various communication devices.

Technical Data

Specifications : ITD-S/WS 113C

Conductor : The central conductor is made of solid electrolytic grade of copper.

Insulation : Premium quality grade polyethylene used on a special extruder. This offers for low attenuation.

Twisted Pairs : The cores are carefully twisted with optimal lays and bunched together to deliver minimised cross talk.

Jacket : Specially formulated flame retardant (FR) PVC.

Marking : The cables are marked 'RATNACOM FR’

Packing : Available in 90 mtr. length in polybag. Higher lengths available on special request.

Cable Design Parameters

Part Numbers Size (mm) No. of Pairs Approx. Overall Diameter (mm)
010600221040 0.4 2 3.9
010600321040 0.4 3 4.3
010600421040 0.4 4 4.7
010600521040 0.4 5 5.2
010601021040 0.4 10 6.5
010602021040 0.4 20 9.2
010600221050 0.5 2 4.2
010600321050 0.5 3 4.7
010600421050 0.5 4 5.1
010600521050 0.5 5 5.7
010601021050 0.5 10 7.0
010602021050 0.5 20 10.0

Electrical Parameters

Electrical Parameters Size
0.5 mm 0.4 mm
DC conductor resistance 92.20 Ω/Km at 20°C max. 143.0 Ω/Km at 20°C max.
Mutual capacitance 50 nF/km max.
Insulation resistance in air 10000 M-Ω/Km
Capacitance unbalance – pair to pair 250 pF/100m max.
Capacitance unbalance – pair to ground 330 pF/100m max.
Resistance unbalance 5% max.